<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-18 06-52-01
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 56 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 71 kHz 12710 5,3895
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,7 dBr 5,30 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 71 kHz MIN: 11 kHz % above 76 kHz: 5,3895 Acquired: 2025/10/18 6.50.57 Total samples: 12710 Equivalent time: 0:10:35 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,1 dBr MIN: 3,7 dBr AVE: 5,30 dBr % above 12,2 dBr: 0,0 Last value: 5,4 dBr (2025/10/18 6.50.57) 06.38 06.40 06.42 06.44 06.46 06.48 06.50 0 2 4 6 Pm [dBr]